Linux cli command hwloc-gather-cpuid
2 minute read
NAME 🖥️ hwloc-gather-cpuid 🖥️
gather-cpuid - Dumps the relevant x86 cpuid values for later (possibly offline) usage
SYNOPSIS
hwloc-gather-cpuid [options] [<outdir>]
OPTIONS
-c <idx>
Only gather cpuid values for logical processor whose OS/physical index is <idx>.
-q –quiet -s –silent
Do not show verbose messages.
–version
Report version and exit.
-h –help
Display help message and exit.
DESCRIPTION
hwloc-gather-cpuid dumps all the relevant x86 cpuid values into subdirectory cpuid of current directory, or in <outdir> if specified.
These files can be used later to explore the machine topology offline, for instance by setting the environment variable HWLOC_CPUID_PATH to the directory containing all output files, and by forcing the x86 backend with HWLOC_COMPONENTS=x86,stop.
The directory contents may also be submitted to hwloc developers to debug issues remotely.
If - is used as <outdir>, the output is dumped to the standard output, but a unique logical processor must have been given with -c.
hwloc-gather-cpuid is a x86 specific tool, it cannot be used on other platforms.
NOTE: hwloc-gather-cpuid gathers many hardware details about the platform. Output files should not be posted on public lists or websites unless it is clear that they contain no sensitive information.
NOTE: The output of hwloc-gather-cpuid is included in the tarball saved by hwloc-gather-topology on Linux/x86.
NOTE: It is highly recommended that you read the hwloc(7) overview page before reading this man page.
EXAMPLES
To store cpuid information of all logical processors of the current machine:
$ hwloc-gather-cpuid Gathering in directory ./cpuid … Gathering CPUID of PU P#0 in path ./hwloc-x86-cpuid/pu0 … Gathering CPUID of PU P#1 in path ./hwloc-x86-cpuid/pu1 … Gathering CPUID of PU P#2 in path ./hwloc-x86-cpuid/pu2 … Gathering CPUID of PU P#3 in path ./hwloc-x86-cpuid/pu3 … Summary written to ./cpuid/hwloc-cpuid-info
RETURN VALUE
Upon successful execution, hwloc-gather-cpuid will exit with the code 0.
hwloc-gather-cpuid will return nonzero exit status if any kind of error occurs, such as (but not limited to) failure to create the output files.
SEE ALSO
hwloc(7), hwloc-gather-topology(1), lstopo(1)
░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░
█║▌│║█║▌★ KALI ★ PARROT ★ DEBIAN 🔴 PENTESTING ★ HACKING ★ █║▌│║█║▌
██╗ ██╗ ██████╗ ██████╗ ██╗ ██╗███████╗██████╗
████████╗██╔══██╗██╔═══██╗╚██╗██╔╝██╔════╝██╔══██╗
╚██╔═██╔╝██║ ██║██║ ██║ ╚███╔╝ █████╗ ██║ ██║
████████╗██║ ██║██║ ██║ ██╔██╗ ██╔══╝ ██║ ██║
╚██╔═██╔╝██████╔╝╚██████╔╝██╔╝ ██╗███████╗██████╔╝
╚═╝ ╚═╝ ╚═════╝ ╚═════╝ ╚═╝ ╚═╝╚══════╝╚═════╝
█║▌│║█║▌ WITH COMMANDLINE-KUNGFU POWER █║▌│║█║▌
░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░
Feedback
Was this page helpful?
Glad to hear it! Please tell us how we can improve.
Sorry to hear that. Please tell us how we can improve.